ASTi Telestra User Guide (Ver. 2, Rev. L.1)
148 Copyright © 1999-2006 Advanced Simulation Technology inc.
DACS Settings
DACS: IP Address
Class: Required
This setting is required for each DACS system you wish to access via the Telestra
RMS server.
This is the IP address for a specific DACS system on the network. Each DACS system will
have at least one network interface (but can have more), and each card will have its own IP
address.
For DACS with only one ethernet card, this is the IP address of that single card.
For DACS with two ethernet cards, this is the IP address of the DIS (or HLA) interface for
systems on a DIS (or HLA) network, not the host interface.
DACS: Name
Class: Recommended
This is the user-specified name for a DACS system.
This will help you differentiate between machines based on something other than their IP
addresses alone.
This description will be displayed in the “DACS Systems” frame that is displayed by clicking
on the “Find DACS” menu option in the RMS menu (orange blocks) at the top of the screen.
ASTi recommends that you keep this setting brief, yet specific.
This field is not required for the RMS server to function properly.
DACS: Description
Class: Recommended
The RMS system allows you to enter descriptions for DACS systems on the network. This will
help you differentiate between machines based on something other than their IP addresses
alone.
This field is not required for the RMS server to function properly.