ASTi Telestra 4 Quick Start (Ver. 1, Rev. E)
8 Copyright © 2011 Advanced Simulation Technology inc.
3.0. Setting up the Telestra 4 Target
To complete the set up you will need the following hardware:
• monitor
• keyboard
• ACE Studio Development Workstation
• Category 5e cable or better
• Target
Follow the steps below to setup the Target and assign an IP address.
1. Connect the monitor and keyboard to the Target.
2. Using a Category 5e cable, connect the Target to the ASTiNet/DIS network using Eth0.
See “Top Level Hardware Layout” on page 1.
3. Power on the Target and allow it to boot.
4. Login with the following:
Username: root Password: abcd1234
5. The Target will not have an IP address without a DHCP network connection. To set an IP
address, type:
ace-net-config -a xxx.xxx.xxx.xxx -n yyy.yyy.yyy.yyy
where ‘x.x.x.x’ is the IP address and ‘y.y.y.y’ is the subnet mask.
This sets the IP address and netmask for Eth0 which is used to access the Remote Man-
agement System (RMS) via a web browser.
6. Optional: For more network setup options type:
ace-net-config -h
7. Once you have configured Eth0, you can use RMS to make additional changes to the net-
work settings.
8. On the development workstation or any computer on the network with a web browser,
open a browser and in the address bar type in the IP address to open the Remote Manage
-
ment System (RMS).
Note: Depending on your web browser and browser version, the browser may show a
failed connection due to a self signed security certificate. Bypass the warning by following
the prompts to add a security exception.